图片展示
En
  • En
  • عربي
  • 한국어
  • Malay
  • ภาษาไทย
  • IndonesiaName
  • Tiếng Việt

NEWS CENTER

NEWS CENTER

Electrical-Grade Aluminum Busbar: Aluminum Bus Bars for Switchgear, Transformers and PV Combiner Connections

2026-11-27 15:22:03

Click:

“ YI-RIVER ALUMINUM supplies 1060/1350 electrical-grade aluminum busbar with stable conductivity, precision cutting, bending, punching and tin plating for switchgear, transformers, PV combiner boxes and BESS busbars, with bulk export supply. ”

Electrical-grade aluminum busbar — also called aluminum bus bar or current-carrying bus — is a solid bar conductor rolled or extruded from electrical-grade pure aluminum and then precision cut to length. It replaces copper busbar in whole or in part to carry and distribute current inside power distribution equipment. YI-RIVER ALUMINUM (Luoyang Yuxin Aluminum) supplies 1060 and 1350 electrical-grade busbar on a stable basis, with cut-to-length precision sawing, bending, hole punching, chamfering and deburring, plus fabrication to customer drawings and mill test documentation on chemical composition and electrical conductivity. The material suits switchgear, transformers, PV combiner boxes, battery energy storage systems and other overseas electrical engineering projects.


Stable Electrical Conductivity with a Traceable Ampacity Design

The core specifications of electrical-grade busbar are resistivity and conductivity. Grade 1350 is an EC (electrical conductor) grade aluminum with conductivity reaching above 61% IACS under international standards; grade 1060 also delivers consistent conductive performance. With controlled impurity content and porosity in the base metal, current density distributes evenly across the cross-section, so long-term current flow is less likely to cause localized overheating.

In practical selection, aluminum conductivity is roughly 60% that of copper, so the cross-section must be enlarged for the same ampacity — engineering practice typically upsizes one to two steps above the equivalent copper bar. For high-current, long-run projects with defined heat dissipation conditions, aluminum busbar can meet the current-carrying requirement while substantially reducing conductor weight and material cost, and easing the mechanical load on the enclosure.


Clear Lightweight Advantage, Lower Total System Cost

Aluminum density is about one third that of copper. For the same volume, aluminum busbar is far lighter, which reduces the burden on transport, lifting and internal enclosure supports — particularly valuable for container-load export orders where ocean freight is cost-sensitive.

Aluminum prices fluctuate less sharply than copper, making raw material cost easier to budget, and domestic EC-grade aluminum supply is steady enough to support long-term volume projects. Aluminum is 100% recyclable with high scrap value, so end-of-life recovery also compares favorably with most metal conductors.


Controlled Fabrication Accuracy with Finished-Part Delivery

Busbar can be cut, bent, punched, slotted, chamfered and deburred to customer drawings, producing clean cuts with minimal burrs and reducing on-site rework. Volume orders can be cut to fixed lengths and packed in groups coded to the enclosure type, so overseas assembly teams can match parts directly on site.

Surface options include anodizing, tin plating and heat-shrink insulation sleeving. Tin plating helps suppress oxidation and stabilize the contact interface; anodizing suits applications with appearance and corrosion-resistance requirements. Contact-surface flatness and overlap area directly affect temperature rise, so the overlap method and bolt specification should be fixed at the drawing stage.



Specifications and Fabrication Options

• Common grades: 1060 and 1350 electrical-grade pure aluminum

• Thickness: 2mm–20mm, sized to ampacity requirements

• Width: 20mm–200mm, with non-standard widths available

• Length: standard 6m, cut-to-length to project dimensions

• Temper: O (soft), H112, H24 and others, selected by bending requirement

• Processing: precision sawing, bending, punching, slotting, chamfering, deburring, tin plating, anodizing, heat-shrink sleeving

• Testing: chemical composition, electrical conductivity, tensile strength, dimensional tolerance; mill certificate and test report available

Main Application Scenarios

• Power distribution equipment: bus connections inside LV/HV switchgear, ring main units and distribution panels

• Transformers and storage: transformer lead bars, BESS pack busbars, inverter internal connections

• Renewable generation: PV combiner box busbars, combiner bus bars, module string conductive parts

• Industrial electrical: rectifier equipment, electroplating power supplies, electrolytic cell busbars, busways

• Transport and charging: EV charger internal conductors, rail transit distribution connectors

Overseas Procurement Checklist

1. Confirm the grade: specify 1350 where conductivity is the governing requirement; 1060 where strength and cost balance matters. Agree the conductivity value and acceptance standard before ordering.

2. Size the cross-section: calculate from actual ampacity, ambient temperature and installation heat dissipation. Copper-to-aluminum replacement projects must be recalculated with the upsize factor — never cut to the original copper dimensions.

3. Fix overlap and bolting: define overlap length, bolt pitch and hole diameter at drawing stage, since contact-surface flatness drives temperature rise.

4. Choose surface treatment: tin plating or anti-oxidation treatment for humid and coastal environments; mill finish precision cutting is adequate for dry enclosure interiors.

5. State tolerances: thickness, width tolerance and straightness must be written into the contract; insufficient straightness on long bars complicates field assembly.

6. Export packing: layer-separated paper, moisture-barrier film, reinforced wooden pallets and edge protection on long lengths to prevent bending and scratching in sea transit; mill certificate, conductivity report and packing list can be provided.

Procurement note: the common pitfalls in electrical aluminum busbar are mixed or substituted base grades, conductivity below specification, and uncleaned burrs at the cut edge. Burrs raise contact resistance and partial-discharge risk, while poor straightness on long bars undermines assembly accuracy. YI-RIVER ALUMINUM inspects base grade, conductivity and dimensional tolerance batch by batch, and supports sample-first confirmation of grade and fabrication accuracy before volume production is scheduled.

YI-RIVER ALUMINUM (Luoyang Yuxin Aluminum) produces aluminum coil, sheet, strip, circles, foil, embossed sheet and electrical-grade aluminum busbar, supplying overseas electrical equipment manufacturers, new energy contractors, switchgear assemblers and trading companies with customized fabrication and test documentation, and accepting long-term volume export orders.


Author: YUXIN New Materials Technology Co., Ltd
0
Electrical-Grade Aluminum Busbar: Aluminum Bus Bars for Switchgear, Transformers and PV Combiner Connections
YI-RIVER ALUMINUM supplies 1060/1350 electrical-grade aluminum busbar with stable conductivity, precision cutting, bending, punching and tin plating for switchgear, transformers, PV combiner boxes and BESS busbars, with bulk export supply.
Long by picture save/share

INQUIRY

  • Name

  • Email

  • Message

  • SEND

  • Security Code
    Refresh the code
    Cancel
    Confirm
Quick Link
PRODUCT

Furnace

Cast-rolling

Cold Rolling

Tension Correction

Cut

Annealing Oven

Cast Aluminum Coil

Company Introduction

Factory Display

Honors And Qualifications

INQUIRY

  • Name

  • Email

  • Message

  • SEND

  • Security Code
    Refresh the code
    Cancel
    Confirm

洛阳宇信新材料科技有限公司

Copyright © 2025 Luoyang Yuxin New Materials Technology Co., Ltd. All Rights Reserved.  SITEMAP

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.